The equipment was received in an inoperative and visibly dirty condition.
A careful disassembly was performed for a detailed visual inspection.
The technical analysis identified a fault in the IGBT (Insulated Gate Bipolar Transistor), a critical component for power conversion.
The circuit boards underwent a thorough general cleaning to remove dirt and debris that could cause overheating and future failures.
The damaged component (IGBT) was replaced with a new part, ensuring the integrity of the power circuit.
After reassembly, the inverter underwent a series of rigorous bench tests. The ATV312 drive was configured using the SoMove software.
The final test was performed directly on a motor, validating the inverter's functionality and correct frequency conversion.
The equipment was approved, operating efficiently and within factory specifications.